New Study Finds That Use of Masimo SedLine® PSi and DSA May Significantly Reduce Postoperative Delirium
15.11.2021 10:00:00 EET | Business Wire | Press release
Masimo (NASDAQ: MASI) today announced the findings of a prospective study published in Frontiers in Neurology in which Dr. Na Xu and colleagues at Capital Medical University in Beijing investigated whether general anesthesia guided by Masimo SedLine® Brain Function Monitoring parameters on Root® could reduce the incidence of postoperative delirium (POD) in patients undergoing carotid endarterectomy (CEA). Using a combination of SedLine’s Patient State Index (PSi), an index based on processed electroencephalogram (EEG), and the Density Spectral Array (DSA), which represents the power of the EEG on both sides of the brain, to guide anesthesia during the procedure, the researchers found a significantly reduced risk of postoperative delirium, and concluded that patients “may benefit from the monitoring of multiple EEG parameters during surgery.”1
This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20211114005316/en/
Masimo Root® with SedLine® Brain Function Monitoring (Photo: Business Wire)
The researchers noted that cerebral blood supply may be “severely disrupted” during CEA, the gold standard treatment for severe carotid stenosis, and that cerebral function is “highly vulnerable” to even brief changes in oxygen and blood supply, as well as to cerebral vascular diseases like carotid stenosis. POD is a “common yet serious” type of geriatric neurological dysfunction associated with worse short- and long-term prognosis and higher healthcare costs. Noting that the incidence of POD is associated with the duration of EEG suppression during surgery, they sought to investigate whether monitoring multiple processed EEG parameters simultaneously to guide anesthesia during a procedure like CEA could positively impact the incidence of POD, compared to use of a single parameter alone.
The authors enrolled 255 patients scheduled for CEA and divided them randomly into an intervention group (n=127, mean age 62) and a standard group (n=128, mean age 63). In the intervention group, general anesthesia was managed using a combination of Masimo SedLine PSi and DSA monitoring (designed to reduce the risk of intraoperative EEG burst suppression); in the standard group, PSi without DSA monitoring was used. In both groups, patients were also monitored with continuous transcranial Doppler ultrasound and near-infrared spectroscopy (NIRS) (designed to avoid perioperative cerebral hypoperfusion or hyperperfusion). The primary outcome was the incidence of POD, measured using the Confusion Assessment Method, during the first three days after surgery. Secondary outcomes were postoperative hospital length of stay (LOS) and other neurologic complications. A team of neurophysiologists independently reviewed the EEG data acquired by SedLine to calculate the cumulative duration of burst suppression for each patient.
The researchers found that the incidence of POD was significantly lower in the intervention group (7.87% of patients) compared to the standard group (28.91% of patients, p < 0.01). Patients in the intervention group also spent significantly less overall time with EEG suppression. There was no significant difference in the incidence of other neurologic complications.
The researchers concluded, “Processed electroencephalogram-guided general anesthesia management, consisting of PSi combined with DSA monitoring, can significantly reduce the risk of postoperative delirium in patients undergoing CEA. Patients, especially those exhibiting hemodynamic fluctuations or receiving surgical procedures that disrupt cerebral perfusion, may benefit from the monitoring of multiple EEG parameters during surgery.”
Postoperative delirium is an acute state of mental confusion characterized by alterations in attention, consciousness, and disorganized thinking. A common and serious complication, POD afflicts up to 60% of patients after major surgery,2-5 is most common in the elderly,2-5 and occurs in up to 91% of the critically ill.6 POD is associated both with worse short- and long-term outcomes and higher costs,3,6-9 and numerous medical bodies—including the American Society of Anesthesiologists (ASA), the United Kingdom National Institute for Health and Care Excellence, the American Geriatric Society, and the American College of Surgeons—have made the prevention of POD a public health priority.10-13 The ASA’s Brain Health Initiative, dedicated to minimizing the impact of pre-existing cognitive deficits and optimizing the cognitive recovery and perioperative experience for adults 65 years and older undergoing surgery, describes POD as a “major public health issue.”14 The incidence of POD has been associated both with preoperative vulnerabilities and—of key importance to studies such as this—the cumulative duration of intraoperative EEG burst suppression. As the current study and others have found, processed EEG monitoring during surgery, by helping clinicians minimize the duration of burst suppression, may lower the rate of POD.1,15-19
@Masimo | #Masimo
About Masimo
Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes and reduce the cost of care. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.20 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,21 improve CCHD screening in newborns,22 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.23-26 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,27 and is the primary pulse oximetry at 9 of the top 10 hospitals as ranked in the 2021-22 U.S. News and World Report Best Hospitals Honor Roll.28 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb®), oxygen content (SpOC™), carboxyhemoglobin (SpCO®), methemoglobin (SpMet®), Pleth Variability Index (PVi®), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67®, fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97®. Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris® Gateway, iSirona™, Patient SafetyNet, Replica™, Halo ION™, UniView®, UniView :60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com. Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/.
ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.
References
- Xu N, Li L, Wang T, Jiao L, Hua Y, Yao D, Wu J, Ma Y, Tian T, Sun X. Processed Multiparameter Electroencephalogram-Guided General Anesthesia Management Can Reduce Postoperative Delirium Following Carotid Endarterectomy: A Randomized Control Trial. Front Neurol. 12 July 2021. 12:666814. doi: 10.3389/fneur.2021.666814.
- Lipowski ZL. Delirium in the elderly patient. N Engl J Med. (1989) 320:578–82. doi: 10.1056/NEJM198903023200907.
- Khadka J, McAlinden C, Pesudovs K. Cognitive trajectories after postoperative delirium. N Engl J Med. (2012) 367:30–9. doi: 10.1056/NEJMoa1112923.
- Inouye SK, Westendorp RG, Saczynski JS. Delirium in elderly people. Lancet. (2014) 383:911–22. doi: 10.1016/S0140-6736(13)60688-1.
- Bin Abd Razak HR, Yung WY. Postoperative delirium in patients undergoing total joint arthroplasty: a systematic review. J Arthroplasty. (2015) 30:1414–7. doi: 10.1016/j.arth.2015.03.012.
- Salluh JI, Wang H, Schneider EB, Nagaraja N, Yenokyan G, Damluji A, et al. Outcome of delirium in critically ill patients: systematic review and meta-analysis. BMJ. (2015) 350:h2538. doi: 10.1136/bmj.h2538.
- Inouye SK. The dilemma of delirium: clinical and research controversies regarding diagnosis and evaluation of delirium in hospitalized elderly medical patients. Am J Med. (1994) 97:278–88. doi: 10.1016/0002-9343(94)90011-6.
- Crocker E, Beggs T, Hassan A, Denault A, Lamarche Y, Bagshaw S, et al. Long-term effects of postoperative delirium in patients undergoing cardiac operation: a systematic review. Ann Thoracic Surg. (2016) 102:1391–9. doi: 10.1016/j.athoracsur.2016.04.071.
- Mashour GA, Woodrum DT, Avidan MS. Neurological complications of surgery and anaesthesia. Br J Anaesthesia. (2015) 114:194–203. doi: 10.1093/bja/aeu296.
- American Society of Anesthesiologists. Perioperative Brain Health Initiative Website. (2018). Available online at: https://www.asahq.org/brainhealthinitiative (accessed September 16, 2018).
- Mohanty S, Rosenthal RA, Russell MM, Neuman MD, Ko CY, Esnaola NF. Optimal perioperative management of the geriatric patient: a best practices guideline from the American College of Surgeons NSQIP and the American Geriatrics Society. J Am College Surgeons. (2016) 222:930–47. doi: 10.1016/j.jamcollsurg.2015.12.026.
- O’Mahony R, Murthy L, Akunne A, Young J. Synopsis of the National Institute for Health and Clinical Excellence guideline for prevention of delirium. Ann Internal Med. (2011) 154:746–51. doi: 10.7326/0003-4819-154-11-201106070-00006.
- National Institute for Health and Care Excellence. Delirium in Adults. London: National Institute for Health and Care Excellence (2014).
- Brain Health. ASA. https://www.asahq.org/in-the-spotlight/brain-health. Accessed 13 Nov 2021.
- Tang CJ, Jin Z, Sands LP, Pleasants D, Tabatabai S, Hong Y, Leung JM. ADAPT-2: A Randomized Clinical Trial to Reduce Intraoperative EEG Suppression in Older Surgical Patients Undergoing Major Noncardiac Surgery. Anesth Analg 2020; 131(4):1228-1236.
- Radtke FM, Franck M, Lendner J, Krüger S, Wernecke KD, Spies CD. Monitoring depth of anaesthesia in a randomized trial decreases the rate of postoperative delirium but not postoperative cognitive dysfunction. Br J Anaesthesia. (2013) 110:98–105. doi: 10.1093/bja/aet055.
- MacKenzie KK, Britt-Spells AM, Sands LP, Leung JM. Processed electroencephalogram monitoring and postoperative delirium: a systematic review and meta-analysis. Anesthesiology. (2018)129:417–27. doi: 10.1097/ALN.0000000000002323.
- Sieber FE, Zakriya KJ, Gottschalk A, Blute MR, Lee HB, Rosenberg PB, et al. Sedation depth during spinal anesthesia and the development of postoperative delirium in elderly patients undergoing hip fracture repair. Mayo Clin Proc. (2010) 85:18–26. doi: 10.4065/mcp.2009.0469.
- Whitlock EL, Torres BA, Lin N, Helsten DL, Nadelson MR, Mashour GA, et al. Postoperative delirium in a substudy of cardiothoracic surgical patients in the BAG-RECALL clinical trial. Anesth Analg. (2014) 118:809–17. doi: 10.1213/ANE.000000000000002.
- Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com. Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
- Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
- de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
- Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology. 2010:112(2):282-287.
- Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter. Spring-Summer 2012.
- McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety. 2016 Jul;42(7):293-302.
- McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
- Estimate: Masimo data on file.
- http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview.
Forward-Looking Statements
This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo Root ® and SedLine ®, and the combination of Masimo SedLine processed electroencephalogram parameters (“Combined Parameters”) in reducing postoperative delirium. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Root, SedLine, and the Combined Parameters, contribute to positive clinical outcomes and patient safety; risks that the researchers’ conclusions and findings may be inaccurate; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov. Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.
To view this piece of content from cts.businesswire.com, please give your consent at the top of this page.
View source version on businesswire.com: https://www.businesswire.com/news/home/20211114005316/en/
Contact information
Masimo
Evan Lamb
949-396-3376
elamb@masimo.com
About Business Wire
For more than 50 years, Business Wire has been the global leader in press release distribution and regulatory disclosure.
Subscribe to releases from Business Wire
Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.
Latest releases from Business Wire
Horse Powertrain Reveals Lightweight Hybrid V6 System at Beijing Auto Show 202622.4.2026 02:01:00 EEST | Press release
Horse Powertrain, a global leader in innovative and low-emission powertrain systems, has revealed the HORSE W30 – the company’s first production-ready V6 engine – ahead of the Beijing Auto Show 2026. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260421176701/en/ The front view of the HORSE W30 engine. The HORSE W30 marks a first for Horse Powertrain, in transferring its expertise in developing optimized three- and four-cylinder engines into the V6 category. By deploying its expertise in this way, Horse Powertrain has developed the lightest V6 on the market and created a hybrid-first V6 with outstanding fuel economy and efficiency. The HORSE W30 is a 3-liter engine that can be fitted in a transverse or longitudinal configuration, allowing it to be packaged in a wide variety of vehicles. The two rows of cylinders are offset at an angle of 90° to lower the engine’s center of gravity, improving ease of installation and optimizi
Horse Powertrain Reveals Lightweight Hybrid V6 System at Beijing Auto Show 202622.4.2026 02:01:00 EEST | Press release
Horse Powertrain, a global leader in innovative and low-emission powertrain systems, has revealed the HORSE W30 – the company’s first production-ready V6 engine – ahead of the Beijing Auto Show 2026. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260421176701/en/ The front view of the HORSE W30 engine. The HORSE W30 marks a first for Horse Powertrain, in transferring its expertise in developing optimized three- and four-cylinder engines into the V6 category. By deploying its expertise in this way, Horse Powertrain has developed the lightest V6 on the market and created a hybrid-first V6 with outstanding fuel economy and efficiency. The HORSE W30 is a 3-liter engine that can be fitted in a transverse or longitudinal configuration, allowing it to be packaged in a wide variety of vehicles. The two rows of cylinders are offset at an angle of 90° to lower the engine’s center of gravity, improving ease of installation and optimizi
Montrose Environmental Group Is Now Onterris21.4.2026 23:05:00 EEST | Press release
Montrose Environmental Group (NYSE: MEG, changing to ONT May 4, 2026) will mark Earth Day by rebranding to Onterris. The new, unified brand reflects a purpose and broader role in tackling complex environmental challenges with scientific rigor, operational quality and precise execution. It also aligns expertise and market awareness to position the Company for its next phase of growth. Founded 14 years ago and operating across the U.S., Canada and Australia, the Company is a leading pure-play environmental solutions provider. While the name is new, the mission remains unchanged: advancing our way of life without compromising the integrity of our environment. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260420842892/en/ At the heart of the new brand is a guiding principle: For Planet & Progress. “Onterris is more than a new name. This brand reflects our company’s evolution and role in solving some of the defining environmenta
Montrose Environmental Group Is Now Onterris21.4.2026 23:05:00 EEST | Press release
Montrose Environmental Group (NYSE: MEG, changing to ONT May 4, 2026) will mark Earth Day by rebranding to Onterris. The new, unified brand reflects a purpose and broader role in tackling complex environmental challenges with scientific rigor, operational quality and precise execution. It also aligns expertise and market awareness to position the Company for its next phase of growth. Founded 14 years ago and operating across the U.S., Canada and Australia, the Company is a leading pure-play environmental solutions provider. While the name is new, the mission remains unchanged: advancing our way of life without compromising the integrity of our environment. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260420842892/en/ At the heart of the new brand is a guiding principle: For Planet & Progress. “Onterris is more than a new name. This brand reflects our company’s evolution and role in solving some of the defining environmenta
SBC Medical Announces Closing of Previously Announced Secondary Public Offering of 3.1 million shares of Common Stock21.4.2026 23:00:00 EEST | Press release
SBC Medical Group Holdings Incorporated (Nasdaq: SBC) (“the Company”), a Management Service Organization operating a wide range of franchise businesses across diverse medical fields, today announced the closing of its previously announced underwritten secondary public offering of 3,100,000 shares of the Company’s common stock by Dr. Yoshiyuki Aikawa (the “Selling Stockholder”) at the public offering price of $3.25 per share. The proceeds from the offering to the Selling Stockholder were approximately $10.1 million, before deducting underwriting discounts and commissions. The Company did not sell any shares of its common stock in the offering. The Selling Stockholder received all of the proceeds from the offering. Maxim Group LLC acted as the sole book-running manager and Roth Capital Partners acted as the co-manager for the offering. The offering was made pursuant to the Company’s effective shelf registration statement on Form S-3, including a base prospectus, filed with the U.S. Secur
In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.
Visit our pressroom