Business Wire

New Study Investigates the Ability of Masimo ORi™ to Provide Early Warning of Hypoxemia During Endotracheal Intubation in ICU Patients

Share

Masimo (NASDAQ: MASI) announced today the findings of a prospective, blinded observational study published in Annals of Intensive Care in which Dr. Jean-Baptiste Lascarrou and colleagues at the Centre Hospitalier Universitaire in Nantes, France evaluated the ability of Masimo ORi™ to predict mild hypoxemia during endotracheal intubation (ETI) in ICU patients.1 They concluded that the time between decrease in ORi and subsequent decrease in oxygen saturation (SpO2) “may allow preventive action,” and that a higher ORi value during preoxygenation was “independently protective against hypoxemia.”

This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20210905005031/en/

To view this piece of content from mms.businesswire.com, please give your consent at the top of this page.

Masimo Root® with ORi™ (Photo: Business Wire)

ORi, available outside the U.S., is a noninvasive and continuous trending index that extends oxygen monitoring on patients on supplemental oxygen. Enabled by the multi-wavelength rainbow® Pulse CO-Oximetry platform, ORi is provided alongside oxygen saturation (SpO2) measured by clinically proven Masimo SET® pulse oximetry.

Noting the importance of optimizing preoxygenation in patients needing ETI, the researchers sought to evaluate whether ORi could provide early warning of impending hypoxemia during the procedure, because ORi “supplies information beyond the range explored by SpO2.” Of the 51 patients who met the inclusion criteria, ORi (alongside SpO2) was monitored using Masimo Radical-7® Pulse CO-Oximeters® and rainbow® fingertip sensors when preoxygenation began. Values were recorded every two seconds, and attending clinicians were not aware of these values. The primary endpoint measured was the time between ORi decreasing below 0.4 and the onset of mild hypoxemia (defined as SpO2 < 97%). Secondarily, the investigators evaluated whether a decline in ORi during preoxygenation predicted the occurrence of mild hypoxemia during ETI.

Analyzing areas under the ROC curve, the researchers found that ORi during preoxygenation predicted SpO2 < 97% during intubation (0.73; 95% confidence interval of 0.58 – 0.88). By contrast, SpO2 at the end of preoxygenation was “poorly predictive” (0.54; 95% CI 0.40 – 0.67). Using univariate analysis, they found that a higher ORi value during preoxygenation was associated with a less frequent occurrence of SpO2 < 97% (odds ratio of 0.09; 95% CI 0.01 – 0.69, p = 0.0199) and that “the highest ORi value during preoxygenation remained significantly associated with a lower risk of SpO2 < 97% during ETI, after adjustment for ETI duration and BMI (odds ratio of 0.76; 95% CI 0.61 – 0.95, p = 0.0141).”

The researchers concluded, “The median time between the ORi decrease below 0.4 and the SpO2 decrease below 97% during the apneic period was 81 seconds [34–146]. A higher ORi during preoxygenation was independently associated with a lower risk of mild hypoxemia (SpO2 < 97%).”

The researchers noted that the median 81 seconds of forewarning “may allow immediate intubation, early face-mask ventilation, insertion of a supraglottic device, or a call for help in the event of intubation difficulties.” In addition, they noted that “ORi monitoring can help identify patients who do not increase their oxygen reserve despite preoxygenation and are therefore at [increased] risk of desaturation during ETI. These patients may benefit from a longer preoxygenation period and/or a change in device.” The authors further noted that “an ORi decline might lead to the detection of a fault in the preoxygenation technique such as an insufficient oxygen flow rate or major leaks.”

As a study limitation, the authors noted that their findings cannot be generalized to ICU patients who did not meet the inclusion criteria, as those patient cohorts remain to be evaluated. The inclusion criteria for this study were ICU admission with a need for ETI and an SpO2/FiO2 ratio above 214. The SpO2/FiO2 ratio was measured during noninvasive ventilation or high-flow oxygen therapy; for conventional oxygen therapy, the fraction of inspired oxygen (FiO2) was calculated as FiO2 = 0.21 + O2 [rate in L/min] x 0.03.

ORi has not received FDA 510(k) clearance and is not available for sale in the United States.

@Masimo | #Masimo

About Masimo

Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes, reduce the cost of care, and take noninvasive monitoring to new sites and applications. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.2 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,3 improve CCHD screening in newborns,4 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.5-8 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,9 and is the primary pulse oximetry at 9 of the top 10 hospitals as ranked in the 2021-22 U.S. News and World Report Best Hospitals Honor Roll.10 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb®), oxygen content (SpOC™), carboxyhemoglobin (SpCO®), methemoglobin (SpMet®), Pleth Variability Index (PVi®), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67®, fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97®. Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris® Gateway, iSirona™, Patient SafetyNet, Replica™, Halo ION™, UniView®, UniView :60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com. Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/.

ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.

References

  1. Hille H, Le Thuaut A, Canet E, Lemarie J, Crosby L, Ottavy G, Garret C, Martin M, Seguin A, Lamouche-Wilquin P Morin J, Zambon O, Miaihle AF, Reignier J, Lascarrou JB. Oxygen reserve index for noninvasive early hypoxemia detection during endotracheal intubation in intensive care: the prospective observational NESOI study. Ann. Intensive Care. 2021 11:112. DOI: 10.1186/s13613-021-00903-8.
  2. Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com. Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
  3. Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
  4. de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
  5. Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology. 2010:112(2):282-287.
  6. Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter. Spring-Summer 2012.
  7. McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety. 2016 Jul;42(7):293-302.
  8. McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
  9. Estimate: Masimo data on file.
  10. http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview.

Forward-Looking Statements

This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo ORi™. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks that findings in the new study on Masimo ORi's ability to predict hypoxemia during ETI cannot be generalized; risks that researchers’ conclusion on the practical applications of Masimo ORi’s forewarning ability may not be accurate; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo ORi, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov. Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.

To view this piece of content from cts.businesswire.com, please give your consent at the top of this page.

Contact information

Media Contact:
Masimo
Evan Lamb
949-396-3376
elamb@masimo.com

About Business Wire

For more than 50 years, Business Wire has been the global leader in press release distribution and regulatory disclosure.

Subscribe to releases from Business Wire

Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.

Latest releases from Business Wire

Venture Global and Tokyo Gas Announce 20-Year LNG Sales and Purchase Agreement26.11.2025 02:00:00 EET | Press release

Today, Venture Global, Inc. (NYSE: VG) and Tokyo Gas Co., Ltd announced the execution of a new, long-term liquefied natural gas (LNG) Sales and Purchase Agreement (SPA). Under the SPA, Tokyo Gas will procure 1 million tonnes per annum (MTPA) of LNG from Venture Global for 20 years, starting in 2030. This deal marks 7.75MTPA of SPAs signed by Venture Global in the last six months. “With nearly 8 MTPA of new long-term commitments signed this year, Venture Global is pleased to build on our commercial momentum through this new partnership with Tokyo Gas,” said Venture Global CEO Mike Sabel. “Tokyo Gas is a pioneer in the LNG industry and leading provider of natural gas to Japan, and we look forward to working with them as we grow our position as a top LNG supplier to Japan. This agreement will contribute significantly to the US-Japan balance of trade over the duration of the SPA, providing Japan with affordable, reliable American LNG.” About Venture Global Venture Global is an American pro

Airship Study: No-Code Native App Experiences Double Purchase Frequency (+140%), Offering Path to Profitable Holiday Growth26.11.2025 01:08:00 EET | Press release

Mobile-first customer experience company Airship today released new aggregate data analysis findings showing that no-code native app experiences significantly increase conversion for key lifecycle events and more than double purchase frequency. The Airship "Experience Impact” research, which studied over 1,000 in-app retail experiences and 1.7 billion device sessions, quantifies the impact of optimizing end-to-end customer journeys—not just sending messages—using no-code and AI-powered tools to drive loyalty and retention at scale, leading to sustainable profitability in a volatile economic environment. Key Findings Customers exposed to high-impact no-code native app experiences such as optimized onboarding flows, dynamic surveys, or embedded personalized offers, purchase 140% more frequently than app customers who don’t receive them. These experiences, which product owners and marketers can create and adapt without developer resources, significantly increase conversion for key lifecyc

Court Finds That Two Advanced Cell Diagnostics Patents Are Not Infringed by Molecular Instruments’ Proprietary HCR™ RNA-ISH Technology25.11.2025 18:30:00 EET | Press release

Molecular Instruments, Inc. announced today that the Unified Patent Court (UPC) of the European Union has found that Molecular Instruments’ HCR™ RNA-ISH technology does not infringe two patents owned by Advanced Cell Diagnostics, Inc. (a Bio-Techne group company). In a 2024 lawsuit filed in the UPC (proceedings no. UPC CFI 187/2024), Advanced Cell Diagnostics alleged that Molecular Instruments’ HCR™ RNA-ISH technology infringes European patents (EP) 2,500,439 and 1,910,572. The Court in its judgment of 18 November 2025 has rejected that claim and dismissed all of Advanced Cell Diagnostics' lawsuit, ruling that the patents are not infringed either literally or by equivalence (UPC Judgment). This 2025 UPC judgment follows on the heels of an April 2024 UK judgment in which the High Court of England and Wales had already dismissed an earlier infringement lawsuit by revoking the UK parts of the same two Advanced Cell Diagnostics patents (proceedings no. HP-2022-000026), ruling that they wer

Andersen Consulting Bolsters Capabilities with BMA25.11.2025 16:30:00 EET | Press release

Andersen Consulting broadens its sustainability and business transformation capabilities through a Collaboration Agreement with BMA, a South Africa-based firm advancing manufacturing competitiveness and inclusive industrial growth. Established over two decades ago, BMA works across manufacturing value chains—from producers to their clients—alongside government and development agencies to drive sustainable industrial competitiveness. Through its sector-focused industrial clusters, the firm delivers integrated services spanning industrial policy and strategy development, value chain strategy, manufacturing competitiveness and lean consulting, decarbonization and SME development—aligning stakeholders around shared priorities and scalable, long-term solutions. “Sustainable manufacturing goes beyond efficiency. It’s about creating ecosystems that are regenerative, resilient, and strategically aligned with long-term growth,” said Rob Stewart, CEO of BMA. “Many of the organizations we work wi

Pure Lithium Receives Saudi Patent for Vertically Integrated Lithium Metal Battery Technology25.11.2025 15:20:00 EET | Press release

Pure Lithium Corporation, a disruptive lithium metal battery technology company, is pleased to announce that the Kingdom of Saudi Arabia has granted the company a foundational patent titled “Vertically Integrated Pure Lithium Metal Production and Lithium Battery Production.” This broad patent covers technology that combines lithium extraction, anode production and battery manufacturing. Pure Lithium’s Brine to Battery™ is a registered trademark in the Kingdom of Saudi Arabia, planting a strong base of intellectual property in the region. “The technology is particularly relevant to Saudi Arabia because it is one of the places in the world with lithium-containing brines, and even has an abundance of vanadium, which is used in our second-generation battery,” said Founder, Chairman and CEO Emilie Bodoin. “In order to displace today’s lithium-ion battery, our vision is to create global battery hubs with closed loop supply chains, not just in the U.S., but in the many places in the world whe

In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.

Visit our pressroom
World GlobeA line styled icon from Orion Icon Library.HiddenA line styled icon from Orion Icon Library.Eye